Environmental burden data (by works) of the Hitachi Cable Group are as follows:

 

CO2 Emissions/Waste Data

 

Domestic sites

 
 
Company name · Location CO2
Emissions
(t)
Waste/Reusable Resources
Volume Generated (t) Recycled Volume (t) Final disposal volume (t) Final Disposal Rate (%)
Hitachi Cable, Ltd.
Densen Works
3-1-1 Sukekawa-cho,
Hitachi City, Ibaraki
Prefecture
23,865
(29,052)
1,948 1,400 3.7 0.2
Hitachi Cable, Ltd.
Hitaka Works
5-1-1 Hitaka-cho, Hitachi City, Ibaraki Prefecture
29,872
(35,743)
10,346 9,002 28.2 0.3
Hitachi Cable, Ltd.
Takasago Works
880 Sunazawa-cho, Hitachi City, Ibaraki Prefecture
35,078
(42,841)
Hitachi Cable, Ltd.
Minato Works
4-5862-2 Kuji-cho, Hitachi City, Ibaraki Prefecture
2,560
(3,181)
Hitachi Cable, Ltd.
Toyoura Works
4-10-1 Kawajiri-cho, Hitachi City, Ibaraki Prefecture
45,506
(52,322)
6,828 6,439 0.9 0.01
Hitachi Cable, Ltd.
Tsuchiura Works
3550 Kidamari-cho, Tsuchiura City, Ibaraki Prefecture
59,414
(68,831)
6,492 2,370 2.9 0.04
Hitachi Cable MEC-Tech, Ltd. Equipment Works
4-12-1 Hitaka-cho, Hitachi City, Ibaraki Prefecture
801
(979)
178 104 0.0 0
Hitachi Cable Logi-Tech, Ltd. Hitaka Office
5-3-3 Hitaka-cho, Hitachi City, Ibaraki Prefecture
131
(156)
1,728 1,717 0.8 0.05
Hitachi Cable Logi-Tech, Ltd. Tokai Office
150 Terunuma, Tokai Village, Naka County, Ibaraki Prefecture
361
(412)
Hitachi Alloy, Ltd. Kisai Works
254-2 Uchitagaya, Kisaimachi, Kitasaitama County, Saitama Prefecture
8,823
(10,501)
807 683 6.2 0.8
Tonichi Kyosan Cable, Ltd. Ishioka Office
1-1 Aragane, Ishioka City, Ibaraki Prefecture
8,813
(10,885)
4,096 3,533 0 0
Tohoku Rubber Co., Ltd. Headquarters Plant
1-1-12 Minato, Miyagino Ward, Sendai City, Miyagi Prefecture
3,207
(3,821)
448 425 3.2 0.7
Hitachi Cable Precision Co., Ltd Yonezawa Works
901 Hosen-machi, Yonezawa City, Yamagata Prefecture
1,283
(1,776)
1,388 1,363 24.4 1.8
Hitachi Cable Film Device, Ltd.
545 Ichouhata, Chuo City, Yamanashi Prefecture
16,098
(19,367)
1,714 720 0.1 0.01
 
* The following CO2 conversion factors have been used:
  [Fuel] Fuel Category-Specific Emission Factors, Law Concerning the Promotion of the Measures to Cope with Global Warming
 
[Electricity] 2008 Adjusted Emission Factor for Each Power Producer, notification by the Ministry of Economy, Trade and Industry and the Ministry of the Environment; in the "CO2 Emissions" column above, the upper figures are based on the adjusted emission factors, while the lower figures in parentheses are based on the actual emission factors.
 
 
 

Overseas Sites

 
 
Company Name · Location CO2 Emissions (t) Waste/Reusable resources
Volume Generated (t) Recycled Volume (t) Final disposal Volume (t)
Hitachi Cable (Johor) Sdn. Bhd.
Malaysia, Johor Bahru
12,052 492 - -
Shanghai Hitachi Cable Co., Ltd.
Shanghai, China
22,275 1,269 1,109 143
Hitachi Cable (Singapore) Pte.Ltd.
Singapore
12,232 496 108 -
PHCP,Inc.
Dasmarinas, the Philippines
4,192 662 409 58
Thai Hitachi Enamel Wire Co., Ltd.
Chachoengsao, Thailand
19,124 557 153 -
Hitachi Cable (Suzhou) Co., Ltd., Densen Works
Suzhou, China
7,955 332 301 31
 
* Data for six major overseas production sites
* The following CO2 conversion factors have been used:
[Fuel] Fuel Category-Specific Emission Factors, Law Concerning the Promotion of the Measures to Cope with Global Warming
[Electricity] Emission Factors 2003 of the Survey Report of Estimated GHG Emissions Intensity in the Power Sector by Country, compiled by the Japan Electrical Manufacturers' Association
 
 

Air and Water Quality Data

 

Densen Works

 
 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Boiler NOx ppm 150 60 26
 
Water Quality
 
Drainage Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
River Cyanogen mg/l 1 0.5 0.02
Mercury mg/l 0.005 0.0025 0.0008
Boron mg/l 10 5 0.2
Fluorine mg/l 8 4 0.4
Ammonia mg/l 100 50 2
PH   5.8~8.6 6.0~8.4 6.6~8.4
BOD mg/l 160 12.5 4
SS mg/l 200 12.5 7
Oil mg/l 5 2.5 ND
Copper mg/l 3 1.5 0.4
Zinc mg/l 2 1 0.5
Meltable Iron mg/l 10 5 3
 
 

Hitaka Works

 
 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Boiler Metal Melting Furnace NOx ppm 180
150
150
60~135
37
77
Dust g/m3N 0.2
0.1
0.1
0.05
<0.01
<0.01
Lead mg/m3N 10 0.8 <0.1
 
Water Quality
 
Drainage Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
River Lead mg/l 0.1 0.08 0.016
Ammonia mg/l 100 80 0.8
PH   5.8~8.6 6.0~8.4 7.1~8.0
BOD mg/l 160 20 3
SS mg/l 200 30 4
Oil mg/l 5 4 0
Zinc mg/l 2 1.8 0.005
 
 
 

Takasago Works

 
 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Boiler Hot-and-Chilled Water Generator Hydrogen Generator NOx ppm 180
150
106.3~175
60~99
110
39
Dust g/m3N 0.10~0.30 0.01~0.22 0.03
 
 

Minato Works

 
Air
 
Drainage Item Facility name Legal limit Voluntary control value Observed value (maximum)
Boiler Metal Melting Furnace NOx ppm 180 170 89
Dust g/m3N 0.2~0.3 0.1~0.24 0.01
Lead mg/m3N 10 0.8 <0.1
 
 

Toyoura Works

 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Boiler Metal Melting Furnace NOx ppm 180~260 50~150 18~82
Dust g/m3N 0.2~0.3 0.05~0.1 0.006~0.013
 
Water Quality
 
Drainage Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
River Ammonia mg/l 100 80 0.3
PH 5.8~8.6 6.0~8.4 7.4~8.3
BOD mg/l 160 20 6.2
SS mg/l 200 30 3.7
Oil mg/l 5 4 <1
Phenol mg/l 5 0.8 0.34
Copper mg/l 3 2 0.13
Zinc mg/l 2 1.8 0.08
Meltable Iron mg/l 10 8 0.1
 
 

Tsuchiura Works

 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Metal Heating Furnace
Metal Melting Furnace
NOx ppm 180 144 28
Dust g/m3N 0.2 0.16 0.103
 
Water Quality
 
Drainage Item Unit Local Regulation and Regional Agreement Value Voluntary Control Value Observed Value (maximum)
River Fluorine mg/l 0.5 0.4 0.1
Ammonia mg/l 100 80 1.3
PH   6.0~8.6 6.0~8.4 7.3~8.1
BOD mg/l 10 8 5.7
SS mg/l 15 12 6.4
Oil mg/l 3 2.4 0.5
Copper mg/l 1 0.8 0.15
Zinc mg/l 1 0.8 0.05
Meltable Iron mg/l 1 0.8 0.04
Meltable Manganese mg/l 1 0.8 0.01
Nitrogen mg/l 8 6.4 1.3
Phosphorus mg/l 0.5 0.4 0.39
 
 

Hitachi Alloy, Ltd. Kisai Works

 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Metal Heating Furnace
Metal Melting Furnace
NOx ppm 180 144 64
Dust g/m3N 0.1~0.25 0.08~0.16 <0.01
 
Water Quality
 
Drainage Item Unit Local Regulation Value Voluntary Control Value Observed Value (Maximum)
River PH   5.8~8.6*1 6.0~8.4 7.4~8.0
BOD mg/l 25 20 6.8
SS mg/l 60 48 13
Oil mg/l 5*1 4 <1
Zinc mg/l 2*1 1.6 0.36
Nitrogen mg/l 120*1 96 2.3
Phosphorus mg/l 16*1 12.8 0.49
 
*1 Same as the regulation value set by the Japanese government
 
 
 

Tonichi Kyosan Cable, Ltd. Ishioka Works

 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Boiler NOx ppm 300 300 78
Dust g/m3N 0.5 0.5 0.001
 
Water Quality
 
Drainage Item Unit Local Regulation Value Voluntary Control Value Observed Value (Maximum)
River BOD mg/l 25 22 3.9
SS mg/l 40 36 6.0
Nitrogen mg/l 60 54 4.4
Phosphorus mg/l 8 7 0.4
 
 
 

Tohoku Rubber Co., Ltd. Headquarters Plant

 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Boiler Heat Medium Boiler NOx ppm 130~150 130~150 58
Dust g/m3N 0.10~0.15 0.10~0.15 0.01
 
Water Quality
 
Drainage Item Unit Regional Agreement Value Voluntary Control Value Observed Value (Maximum)
Ocean PH   5.8~8.6 6.0~8.4 6.3~7.4
COD mg/l 20 18 9.9
SS mg/l 20 18 14
Oil mg/l 3 2.8 1.3
Zinc mg/l 2*2 - 0.2
 
*2 The regulation value set by the Japanese government presented due to the absence of a value agreed upon among businesses in the region
 
 
 

Hitachi Cable Film Device, Ltd.

 
Air
 
Facility name Item Unit Legal Limit Voluntary Control Value Observed Value (Maximum)
Boiler NOx ppm 150 120 84
Dust g/m3N 0.1 0.08 0.007
 
Water Quality
 
Drainage Item Unit Local Regulation Value Voluntary Control Value Observed Value (Maximum)
River Boron mg/l 10*3 1 0.19
Fluorine mg/l 1 0.7 0.2
Ammonia mg/l 100*3 30 12
PH   5.8~8.6*3 5.8~8.6 6.9~7.9
BOD mg/l 30 20 8.3
SS mg/l 50 30 20
Oil mg/l 5 3 2.0
Phenol mg/l 1 0.7 0.02
Cooper mg/l 1 0.7 0.05
Zinc mg/l 1 0.7 0.06
Meltable Iron mg/l 1 0.7 0.25
Meltable Manganese mg/l 1 0.7 0.09
Chrome mg/l 0.5 0.3 0.02
 
*3 Same as the regulation value set by the Japanese government
 
 
??????



starting of secondary  navigation
Corporate Profile

Research and Development

CSR [ Corporate Social Responsibility ]

CSR Management

Social Contributions through Business

Social Performance

Environmental Performance

Environmental Activities of the Hitachi Cable Group

Environmental Management Status

Environmental Accounting

Environmental Action Plan and Results Evaluation

Input of Resources and Energy and Output to the Environment

Global Warming Prevention

Promoting Recycling of Resources

Chemical Management in Production Activities

Green Procurement

Environmental-conscious Products

Acquisition of ISO14001 Certifications

Site Data [April 2009 - March 2010]

Major Overseas Group Companies

Publish

Procurement
ending of secondary navigation




page top

 
starting of footer  | Terms of Use | What's New | Privacy Policy |ending of footer
Hitachi Cable Home © Hitachi Cable, Ltd. 1997, 2011. All rights reserved.